ifix联系人-设备网电子数据表CreateDate=5-6-2004创时2: 00ModDate=11-9-2004ModTime2: 20: 00修订版=1.3VendCode=562ProdType=0ProdCode=1001MajRev=1MinRev=1VendName=Phoenix联系人ProdTypeStr=Generic设备ProdName=FLMBKDN12DI8M12Catalog=2736343第1类=设备网默认值0x0001PollInfo=0x00010[Params] Param1= 0, $ parameter value slot 6, "20 64 24 01 30 0B", $ link size and path 0x01, $ descriptor 0xC1, 1, $ BOOL data type, 1 byte(s) "Use Status Byte", $ parameter name "", $ units string "Adds a status byte to the produced data.", 0,1,1, 1,1,1,0,0,0,0,0,0!Param2= 0, $ parameter value slot 6, "20 64 24 01 30 0E", $ link size and path 0x01, $ descriptor 0xC1, 1, $ BOOL data type, 1 byte(s) "Pad I/O", $ parameter name "", $ units string "Forces analog/special function modules to begin on even bytes.", 0,1,1, 1,1,1,0,0,0,0,0,0!Param3= 0, $ parameter value slot 6, "20 64 24 01 30 16", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Reserve Digital Inputs", $ parameter name "", $ units string "Reserve Digital Inputs", 0,510,0, 1,1,1,0,0,0,0,0,0!Param4= 0, $ parameter value slot 6, "20 64 24 01 30 17", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Reserve Digital Outputs", $ parameter name "", $ units string "Reserve Digital Outputs", 0,510,0, 1,1,1,0,0,0,0,0,0!Param5= 0, $ parameter value slot 6, "20 64 24 01 30 23", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Reserve Analog Inputs", $ parameter name "", $ units string "Reserve Analog Inputs", 0,128,0, 1,1,1,0,0,0,0,0,0!Param6= 0, $ parameter value slot 6, "20 64 24 01 30 24", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Reserve Analog Outputs", $ parameter name "", $ units string "Reserve Analog Outputs", 0,128,0, 1,1,1,0,0,0,0,0,0!Param7= 0, $ parameter value slot 6, "20 64 24 01 30 20", $ link size and path 0x01, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "Use Control Byte", $ parameter name "", $ units string "Adds the control byte to the consumed data.", 0,1,0, 1,1,1,0,0,0,0,0,0!Param8= 0, $ parameter value slot 6, "20 64 24 01 30 0A", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Add All Mode", $ parameter name "", $ units string "Specifies which modules will be added to produced and consumed data.", 0,65535,15, 1,1,1,0,0,0,0,0,0!Param9= 0, $ parameter value slot 6, "20 64 24 01 30 07", $ link size and path 0x01, $ descriptor 0xC1, 1, $ BOOL data type, 1 byte(s) "Add All I/O", $ parameter name "", $ units string "Reads local bus and adds modules, specified by 'Add All Mode' to produced and consumed data.", 0,1,0, 1,1,1,0,0,0,0,0,0!Param10= 0, $ parameter value slot 6, "20 64 24 01 30 14", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Produce Size", $ parameter name "", $ units string "Produce Size", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param11= 0, $ parameter value slot 6, "20 64 24 01 30 15", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Consume Size", $ parameter name "", $ units string "Consume Size", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param12= 0, $ parameter value slot 6, "20 64 24 01 30 03", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Number of Digital Inputs", $ parameter name "", $ units string "Number of digital inputs to add to produced data.", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param13= 0, $ parameter value slot 6, "20 64 24 01 30 04", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Number of Digital Outputs", $ parameter name "", $ units string "Number of digital outputs to add to consumed data.", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param14= 0, $ parameter value slot 6, "20 64 24 01 30 05", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Number of Analog Inputs", $ parameter name "", $ units string "Number of analog inputs to add to produced data.", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param15= 0, $ parameter value slot 6, "20 64 24 01 30 06", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Number of Analog Outputs", $ parameter name "", $ units string "Number of analog outputs to add to consumed data.", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param16= 0, $ parameter value slot 6, "20 64 24 01 30 0F", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Number of DIP Faults", $ parameter name "", $ units string "Number of DIP faults to add to produced data.", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param17= 0, $ parameter value slot 6, "20 64 24 01 30 10", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Number of DOP Faults", $ parameter name "", $ units string "Number of DOP faults to add to produced data.", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param18= 0, $ parameter value slot 6, "20 64 24 01 30 11", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Number of AIP Faults", $ parameter name "", $ units string "Number of AIP faults to add to produced data.", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param19= 0, $ parameter value slot 6, "20 64 24 01 30 12", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Number of AOP Faults", $ parameter name "", $ units string "Number of AOP faults to add to produced data.", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param20= 0, $ parameter value slot 6, "20 64 24 01 30 13", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Number of Special Faults", $ parameter name "", $ units string "Number of Special Function faults to add to produced data.", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param21= 0, $ parameter value slot 6, "20 65 24 01 30 04", $ link size and path 0x32, $ descriptor 0xD1, 1, $ BYTE data type, 1 byte(s) "Byte 0, Status Word", $ parameter name "", $ units string "Displays current error bits.", 0,255,0, 1,1,1,0,0,0,0,0,0!Param22= 0, $ parameter value slot 6, "20 65 24 01 30 05", $ link size and path 0x10, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "First Faulted Module", $ parameter name "", $ units string "First faulted module.", 0,255,0, 1,1,1,0,0,0,0,0,0!Param23= 0, $ parameter value slot 6, "20 65 24 01 30 07", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Number of Modules", $ parameter name "", $ units string "Number of Modules", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param24= 0, $ parameter value slot 6, "20 65 24 01 30 08", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Number of Bits", $ parameter name "", $ units string "Number of Bits", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param25= 0, $ parameter value slot 6, "20 65 24 01 30 0B", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Local Scans Per Second", $ parameter name "", $ units string "Local Scans Per Second", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param26= 0, $ parameter value slot 6, "20 64 24 01 30 18", $ link size and path 0x03, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "Fault Mode", $ parameter name "", $ units string "Controls how the DeviceNet Interface reacts to a fault.", 0,3,0, 1,1,1,0,0,0,0,0,0!Param27= 0, $ parameter value slot 6, "20 65 24 01 30 0C", $ link size and path 0x30, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Loop Diagnostic Count", $ parameter name "", $ units string "Loop Diagnostic Count during connection failure.", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param28= 0, $ parameter value slot 6, "20 65 24 01 30 0D", $ link size and path 0x30, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "Connection Failure Endpoint #1", $ parameter name "", $ units string "Displays the module number at the first connection failure.", 0,64,0, 1,1,1,0,0,0,0,0,0!Param29= 0, $ parameter value slot 6, "20 65 24 01 30 0E", $ link size and path 0x30, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "Connection Failure Endpoint #2", $ parameter name "", $ units string "Displays the number of the module at the second failed connection.", 0,64,0, 1,1,1,0,0,0,0,0,0!Param30= 0, $ parameter value slot 6, "20 65 24 01 30 0F", $ link size and path 0x03, $ descriptor 0xD1, 1, $ BYTE data type, 1 byte(s) "Latched Status Byte", $ parameter name "", $ units string "Displays the latched value of the last Status byte.", 0,255,0, 1,1,1,0,0,0,0,0,0!Param31= 0, $ parameter value slot 6, "20 65 24 01 30 10", $ link size and path 0x30, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "Latched Faulted Module", $ parameter name "", $ units string "Displays the module that had a problem during the last fault.", 0,64,0, 1,1,1,0,0,0,0,0,0!Param32= 0, $ parameter value slot 6, "20 65 24 01 30 11", $ link size and path 0x30, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "Latched Connection Failure Endpoint #1", $ parameter name "", $ units string "Displays the number of the module at the first connection failure latched during last connection error.", 0,64,0, 1,1,1,0,0,0,0,0,0!Param33= 0, $ parameter value slot 6, "20 65 24 01 30 12", $ link size and path 0x30, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "Latched Connection Failure Endpoint #2", $ parameter name "", $ units string "Displays the number of the module at the second connection failure latched during last connection error.", 0,64,0, 1,1,1,0,0,0,0,0,0!Param34= 0, $ parameter value slot 6, "20 65 24 01 30 13", $ link size and path 0x32, $ descriptor 0xD1, 1, $ BYTE data type, 1 byte(s) "Power Supply Status", $ parameter name "", $ units string "Displays the status of the power supplies connected to the module.", 0,255,0, 1,1,1,0,0,0,0,0,0!Param35= 0, $ parameter value slot 6, "20 64 24 01 30 19", $ link size and path 0x03, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "CRC Fault Mode", $ parameter name "", $ units string "Selects what effect the fault has on the Identity Status.", 0,2,2, 1,1,1,0,0,0,0,0,0!Param36= 0, $ parameter value slot 6, "20 64 24 01 30 1A", $ link size and path 0x03, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "PF Fault Mode", $ parameter name "", $ units string "Selects what effect the fault has on the Identity Status.", 0,2,2, 1,1,1,0,0,0,0,0,0!Param37= 0, $ parameter value slot 6, "20 64 24 01 30 1B", $ link size and path 0x03, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "Power Fault Mode", $ parameter name "", $ units string "Selects what effect the fault has on the Identity Status.", 0,2,2, 1,1,1,0,0,0,0,0,0!Param38= 0, $ parameter value slot 6, "20 64 24 01 30 1C", $ link size and path 0x03, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "Module Change Fault Mode", $ parameter name "", $ units string "Selects what effect the fault has on the Identity Status.", 0,2,2, 1,1,1,0,0,0,0,0,0!Param39= 0, $ parameter value slot 6, "20 64 24 01 30 1D", $ link size and path 0x03, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "Configuring Fault Mode", $ parameter name "", $ units string "Selects what effect the fault has on the Identity Status.", 0,2,2, 1,1,1,0,0,0,0,0,0!Param40= 0, $ parameter value slot 6, "20 64 24 01 30 1E", $ link size and path 0x03, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "Connection Fault Mode", $ parameter name "", $ units string "Selects what effect the fault has on the Identity Status.", 0,2,2, 1,1,1,0,0,0,0,0,0!Param41= 0, $ parameter value slot 6, "20 64 24 01 30 1F", $ link size and path 0x03, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "Fault Cycles Fault Mode", $ parameter name "", $ units string "Selects what effect the fault has on the Identity Status.", 0,2,2, 1,1,1,0,0,0,0,0,0!Param42= 0, $ parameter value slot 6, "20 68 24 01 30 04", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "COS Mask Index", $ parameter name "", $ units string "Index of Byte Value Read or Written to in the COS mask.02550110000000Param43= 0, $ parameter value slot 6, "20 68 24 01 30 05", $ link size and path 0x01, $ descriptor 0xC6, 1, $ data type, 1 byte(s) "COS Byte Value", $ parameter name "", $ units string "This value is used as a mask to determine whether to send a COS message.", 0,255,0, 1,1,1,0,0,0,0,0,0!Param44= 0, $ parameter value slot 6, "20 68 24 01 30 06", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "COS Add All Mode", $ parameter name "", $ units string "Determines which type of Inputs cause a COS message.写时加通COS属性065350110000000Param45= 0, $ parameter value slot 6, "20 68 24 01 30 07", $ link size and path 0x01, $ descriptor 0xC1, 1, $ BOOL data type, 1 byte(s) "COS Add All", $ parameter name "", $ units string "Add All inputs defined in the COS Add All Mode.", 0,1,0, 1,1,1,0,0,0,0,0,0!Param46= 0, $ parameter value slot 6, "20 68 24 01 30 09", $ link size and path 0x01, $ descriptor 0xC1, 1, $ BOOL data type, 1 byte(s) "COS Enable Status Byte", $ parameter name "", $ units string "Causes a COS message to be generated when the Status byte changes value.", 0,1,0, 1,1,1,0,0,0,0,0,0!Param47= 0, $ parameter value slot 6, "20 68 24 01 30 0A", $ link size and path 0x01, $ descriptor 0xC1, 1, $ BOOL data type, 1 byte(s) "COS DIP Fault", $ parameter name "", $ units string "Causes a COS message to be generated when a DIP fault changes.", 0,1,0, 1,1,1,0,0,0,0,0,0!Param48= 0, $ parameter value slot 6, "20 68 24 01 30 0B", $ link size and path 0x01, $ descriptor 0xC1, 1, $ BOOL data type, 1 byte(s) "COS DOP Fault", $ parameter name "", $ units string "Causes a COS message to be generated when a DOP fault changes.", 0,1,0, 1,1,1,0,0,0,0,0,0!Param49= 0, $ parameter value slot 6, "20 68 24 01 30 0C", $ link size and path 0x01, $ descriptor 0xC1, 1, $ BOOL data type, 1 byte(s) "COS AIP Fault", $ parameter name "", $ units string "Causes a COS message to be generated when a AIP fault changes.", 0,1,0, 1,1,1,0,0,0,0,0,0!Param50= 0, $ parameter value slot 6, "20 68 24 01 30 0D", $ link size and path 0x01, $ descriptor 0xC1, 1, $ BOOL data type, 1 byte(s) "COS AOP Fault", $ parameter name "", $ units string "Causes a COS message to be generated when a AOP fault changes.", 0,1,0, 1,1,1,0,0,0,0,0,0!Param51= 0, $ parameter value slot 6, "20 68 24 01 30 0E", $ link size and path 0x01, $ descriptor 0xC1, 1, $ BOOL data type, 1 byte(s) "COS Special Function Fault", $ parameter name "", $ units string "Causes a COS message to be generated when a Special Function fault changes.", 0,1,0, 1,1,1,0,0,0,0,0,0!Param52= 0, $ parameter value slot 6, "20 68 24 01 30 0F", $ link size and path 0x01, $ descriptor 0xC1, 1, $ BOOL data type, 1 byte(s) "COS Enable DIP", $ parameter name "", $ units string "Causes a COS message to be generated when any DIP changes state.", 0,1,0, 1,1,1,0,0,0,0,0,0!Param53= 0, $ parameter value slot 6, "20 68 24 01 30 10", $ link size and path 0x01, $ descriptor 0xC1, 1, $ BOOL data type, 1 byte(s) "COS Enable AIP", $ parameter name "", $ units string "Causes a COS message to be generated when any AIP changes state.", 0,1,0, 1,1,1,0,0,0,0,0,0!Param54= 0, $ parameter value slot 6, "20 68 24 01 30 11", $ link size and path 0x01, $ descriptor 0xC1, 1, $ BOOL data type, 1 byte(s) "COS Enable Special Function",$ parameter name "", $ units string "Causes a COS message to be generated when any Special Function changes state.", 0,1,0, 1,1,1,0,0,0,0,0,0!Param55= 0, $ parameter value slot 6, "20 68 24 01 30 12", $ link size and path 0x01, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "COS AIP Mask Value", $ parameter name "", $ units string "Mask value for Analog Inputs.COS加通065350110000000Param56= 0, $ parameter value slot 6, "20 65 24 01 30 15", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Error History 1", $ parameter name "", $ units string "Most recent Status history", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param57= 0, $ parameter value slot 6, "20 65 24 01 30 16", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Error History 2", $ parameter name "", $ units string "Error History entry 2", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param58= 0, $ parameter value slot 6, "20 65 24 01 30 17", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Error History 3", $ parameter name "", $ units string "Error History entry 3", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param59= 0, $ parameter value slot 6, "20 65 24 01 30 18", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Error History 4", $ parameter name "", $ units string "Error History entry 4", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param60= 0, $ parameter value slot 6, "20 65 24 01 30 19", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Error History 5", $ parameter name "", $ units string "Error History entry 5", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param61= 0, $ parameter value slot 6, "20 65 24 01 30 1A", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Error History 6", $ parameter name "", $ units string "Error History entry 6", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param62= 0, $ parameter value slot 6, "20 65 24 01 30 1B", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Error History 7", $ parameter name "", $ units string "Error History entry 7", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param63= 0, $ parameter value slot 6, "20 65 24 01 30 1C", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Error History 8", $ parameter name "", $ units string "Error History entry 8", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param64= 0, $ parameter value slot 6, "20 65 24 01 30 1D", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Error History 9", $ parameter name "", $ units string "Error History entry 9", 0,65535,0, 1,1,1,0,0,0,0,0,0!Param65= 0, $ parameter value slot 6, "20 65 24 01 30 1E", $ link size and path 0x10, $ descriptor 0xC7, 2, $ UINT data type, 2 byte(s) "Error History 10", $ parameter name "", $ units string "Last saved Status history", 0,65535,0, 1,1,1,0,0,0,0,0,0!马克斯Inst65描述符9Cfgserm0[EnumPar] Param21="CRC","Peripheral Fault","Power Fault","Module Change","Configuring","Connection Failure","Fault Cycles","Reserved"!spram26=全输出关闭,自恢复运行,带设备网故障数据运行,带I/O数据运行Param30="CRC","Peripheral Fault","Power Fault","Module Change","Configuring","Connection Failure","Fault Cycles","Reserved"!Param34="Communication Power", "Reserved", "US Power", "Reserved","Reserved","Reserved","Reserved","Reserved"!param35=无识别故障 minor可恢复故障 major可恢复故障param36=无识别故障 minor可恢复故障 major可恢复故障param37表示无识别故障 minor可恢复故障 major可恢复故障param38=无识别故障 minor可恢复故障 major可恢复故障param39=无识别故障 minor可恢复故障 major可恢复故障param40表示无识别故障 minor可恢复故障 major可恢复故障param41=“无识别故障”、“最小可恢复故障”、“大可恢复故障”;